Hotels & hospitality

Hotel and resort projects are sized by peak-hour demand, not by daily average: guests shower within the same morning and evening windows, and the system has to carry both peaks without sending cold water to any room.

Aurora delivers central hotel systems with storage sized on the critical hour, backed by an auxiliary heat source that engages automatically when solar gain is not enough, so service never depends on the weather.

  1. 19projects delivered
  2. 334units installed
  3. 7governorates

What makes a hotel project different

  • Sizing follows the peak hourly draw rather than total daily litres, which is what sets tank volume and tank count.
  • An auxiliary source, electric or boiler, on a thermostat so an overcast day never becomes a guest complaint.
  • A hot-water return loop so distant bathrooms get hot water immediately instead of running the line off.
  • Parallel units instead of one oversized unit, so maintenance happens while the hotel keeps operating.
  • Pipe routes and tank rooms placed so service access never crosses guest areas.

Delivered projects

ProjectGovernorateUnits
Robinson HotelRed Sea125 units
Intercontinental HotelSouth Sinai15 units
Swiss Inn HotelRed Sea45 units
Arabia HotelRed Sea23 units
Ecotel HotelSouth Sinai18 units
Beit El Malakout HotelAlexandria14 units
Bel Air HotelRed Sea13 units
Inmo HotelSouth Sinai12 units
San Giovanni HotelCairo12 units
Amarina Soma Bay HotelRed Sea10 units
Aqua Marine HotelAswan9 units
Makadina HotelRed Sea9 units
Arkan HotelDamietta7 units
Brasil HotelGiza6 units
Sultan Gardens HotelSouth Sinai5 units
Sharm Dreams Al Fairouz HotelSouth Sinai4 units
Three Corners Three Beach HotelRed Sea4 units
Hanoo HotelCairo2 units
Qasr El Kababgy RestaurantsCairo1 unit
See the full projects record

Frequently Asked Questions

Can solar water heaters carry a hotel operating year round?

The solar system covers the larger share of the hot-water load through the year, and the auxiliary source completes it on overcast days and at peak occupancy. The correct design is hybrid, with solar as the primary source and a ready backup, not solar alone.

How do you size a system for a hotel?

We start with a site survey: room count, expected occupancy, the type of draw-off points such as showers, tubs, basins, laundry and kitchen, and the peak hours. From those we derive the critical hourly load, which then sets collector count, storage volume and the auxiliary source.

Does installation disrupt hotel operations?

We work in phases against a schedule agreed with the operations team. Final tie-ins happen during low-occupancy windows, and the system is split into units so one part keeps running while another is connected.

Call AuroraTalk to Shams