Hotels & hospitality
Hotel and resort projects are sized by peak-hour demand, not by daily average: guests shower within the same morning and evening windows, and the system has to carry both peaks without sending cold water to any room.
Aurora delivers central hotel systems with storage sized on the critical hour, backed by an auxiliary heat source that engages automatically when solar gain is not enough, so service never depends on the weather.
- 19projects delivered
- 334units installed
- 7governorates
What makes a hotel project different
- Sizing follows the peak hourly draw rather than total daily litres, which is what sets tank volume and tank count.
- An auxiliary source, electric or boiler, on a thermostat so an overcast day never becomes a guest complaint.
- A hot-water return loop so distant bathrooms get hot water immediately instead of running the line off.
- Parallel units instead of one oversized unit, so maintenance happens while the hotel keeps operating.
- Pipe routes and tank rooms placed so service access never crosses guest areas.
Delivered projects
| Project | Governorate | Units |
|---|---|---|
| Robinson Hotel | Red Sea | 125 units |
| Intercontinental Hotel | South Sinai | 15 units |
| Swiss Inn Hotel | Red Sea | 45 units |
| Arabia Hotel | Red Sea | 23 units |
| Ecotel Hotel | South Sinai | 18 units |
| Beit El Malakout Hotel | Alexandria | 14 units |
| Bel Air Hotel | Red Sea | 13 units |
| Inmo Hotel | South Sinai | 12 units |
| San Giovanni Hotel | Cairo | 12 units |
| Amarina Soma Bay Hotel | Red Sea | 10 units |
| Aqua Marine Hotel | Aswan | 9 units |
| Makadina Hotel | Red Sea | 9 units |
| Arkan Hotel | Damietta | 7 units |
| Brasil Hotel | Giza | 6 units |
| Sultan Gardens Hotel | South Sinai | 5 units |
| Sharm Dreams Al Fairouz Hotel | South Sinai | 4 units |
| Three Corners Three Beach Hotel | Red Sea | 4 units |
| Hanoo Hotel | Cairo | 2 units |
| Qasr El Kababgy Restaurants | Cairo | 1 unit |
Frequently Asked Questions
Can solar water heaters carry a hotel operating year round?
The solar system covers the larger share of the hot-water load through the year, and the auxiliary source completes it on overcast days and at peak occupancy. The correct design is hybrid, with solar as the primary source and a ready backup, not solar alone.
How do you size a system for a hotel?
We start with a site survey: room count, expected occupancy, the type of draw-off points such as showers, tubs, basins, laundry and kitchen, and the peak hours. From those we derive the critical hourly load, which then sets collector count, storage volume and the auxiliary source.
Does installation disrupt hotel operations?
We work in phases against a schedule agreed with the operations team. Final tie-ins happen during low-occupancy windows, and the system is split into units so one part keeps running while another is connected.

